Selecting the interface protocol and setting the in-
verter baud rate
General If a data communication connection is required between the inverter and other Fronius
data communication components, the ‘Interface protocol’ must be set in the ‘Basic Service’
menu.
The following 5-digit access code must be entered to access the ‘Basic Service’ menu:
22742
Entering the ac-
cess code
Press the ‘Menu’ key
‘Menu’ is shown.
Select the ‘Setup’ mode using the ‘Left’
or ‘Right’ keys
Press the unoccupied ‘Menu/Esc’ key
5 x
‘CODE’ is displayed, the first digit flashes.
Enter the access code 22742:
Use the ‘Up’ and ‘Down’ keys to select
a value for the first digit of the access
code
Press the ‘Enter’ key
The second digit flashes.
Repeat steps 4 and 5 for the second,
third, fourth and fifth digit of the access
code until ...
1
2
3
4
5
6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius IG Plus A 3.0-1 UNI and is the answer not in the manual?

Fronius IG Plus A 3.0-1 UNI Specifications

General IconGeneral
AC nominal output3000 W
Max. apparent AC power3000 VA
Max. output current13 A
AC grid frequency50 / 60 Hz
THD<3%
Max. DC voltage500 V
Number of MPP trackers1
AC voltage range183 V - 264 V
DC input voltage range150 - 450 V
CoolingConvection

Related product manuals