118
Class 2 Status
Codes
Status codes of class 2 are typically tempo-
rary. Their cause lies in the grid.
The first reaction of the inverter is to disconnect from the grid. Subsequently, the grid will
be checked for the duration of the observation period stipulated. If after the end of this pe-
riod no further defect is identified, the inverter resumes operating and feeding power into
the grid.
Behavior Grid conditions are thoroughly tested and as soon as they are
again within the permissible range, the inverter will resume
feeding power into the grid.
Remedy Check grid connections and fuses
Should the status code persist, you should contact your system
installer
1x7
No AC grid detected
Behavior Grid conditions are thoroughly tested and as soon as they are
again within the permissible range, the inverter will resume
feeding power into the grid.
Remedy Check grid connections and fuses
Should the status code persist, you should contact your system
installer
108
Islanding detected
Behavior Grid conditions are thoroughly tested and as soon as they are
again within the permissible range, the inverter will resume
feeding power into the grid.
Remedy Should the status code persist, you should contact your system
installer
109
General grid error
This error is always displayed first for grid errors. After reviewing all power stage sets, the
grid error is specified in more detail: 1x1 / 1x4 or the display remains at "109" (e.g., when
2 phases report "104" and one phase "101")
Behavior Grid conditions are thoroughly tested and as soon as they are
again within the permissible range, the inverter will resume
feeding power into the grid.
Remedy Check grid connections and fuses
Should the status code persist, you should contact your system
installer

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius IG Plus A 3.0-1 UNI and is the answer not in the manual?

Fronius IG Plus A 3.0-1 UNI Specifications

General IconGeneral
AC nominal output3000 W
Max. apparent AC power3000 VA
Max. output current13 A
AC grid frequency50 / 60 Hz
THD<3%
Max. DC voltage500 V
Number of MPP trackers1
AC voltage range183 V - 264 V
DC input voltage range150 - 450 V