EasyManuals Logo

Fronius IG Plus A 3.0-1 UNI User Manual

Fronius IG Plus A 3.0-1 UNI
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #125 background imageLoading...
Page #125 background image
123
EN-US
Class 4 status
codes
Class 4 status codes may require the inter-
vention of a trained Fronius service techni-
cian.
401
No internal communication with power stage set
Description The inverter will automatically attempt to connect again and, if
possible, resume feeding power into the grid
Remedy Check grid connections and fuses
If status code persists: Contact a Fronius-trained service tech-
nician
402
Communication with EEPROM not possible
Description The inverter will automatically attempt to connect again and, if
possible, resume feeding power into the grid.
Remedy If status code persists: Contact a Fronius-trained service tech-
nician
403
EEPROM faulty
Description The inverter will automatically attempt to connect again and, if
possible, resume feeding power into the grid.
Remedy If status code persists: Contact a Fronius-trained service tech-
nician
406
One or both temperature sensors are defective
Description The inverter disconnects from the grid for safety reasons.
Remedy If status code persists: Contact a Fronius-trained service tech-
nician
407
Temperature sensor at cooling element defective
Description The inverter disconnects from the grid for safety reasons.
Remedy If status code persists: Contact a Fronius-trained service tech-
nician
408
Direct current feed in
Description The inverter disconnects from the grid for safety reasons.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius IG Plus A 3.0-1 UNI and is the answer not in the manual?

Fronius IG Plus A 3.0-1 UNI Specifications

General IconGeneral
AC nominal output3000 W
Max. apparent AC power3000 VA
Max. output current13 A
AC grid frequency50 / 60 Hz
THD<3%
Max. DC voltage500 V
Number of MPP trackers1
AC voltage range183 V - 264 V
DC input voltage range150 - 450 V