166
General data
Safety equipment
Maximum efficiency 96.2 %
CEC efficiency at 277 V 96.0 %
Night consumption < 1.5 W
Consumption during operation 20 W
Cooling Controlled forced ventilation
Degree of protection NEMA 3R
Unit dimensions w x h x d 48.07 x 17.09 x 9.61 in.
1221 x 434 x 244 mm
Power stage set weight 82 lbs.
37 kg
Connection area weight 26 lbs.
12 kg
Shipping dimensions w x h x d 42.72 x 20.28 x 14.02 in. +
17.72 x 20.28 x 14.02 in.
1085 x 515 x 356 mm +
450 x 515 x 356 mm
Shipping weight 114 lbs.
52 kg
Permissible ambient temperature
(with 95% rel. humidity)
-13 °F - +131 °F
- 25 °C - +55 °C
Permitted storage temperature
(with 95% rel. humidity)
-13 °F - +149 °F
- 25 °C - +65 °C
Ground fault protection internal GFDI
(Ground Fault Detector/Interrupter)
Islanding protection integrated
Protection against reverse polarity integrated
Arc detection / interruption integrated
Over temperature output power derating /
active cooling