3 Maintenance
66
Maintenance
3
4 Pinch both sides of the empty staple case
with your fingers (1), and remove the staple
case from the cartridge (2).
5 Insert the front side of the new staple case
into the staple cartridge (1), and then push
the rear side into the cartridge (2).
6 Push the staple cartridge into the finisher
until it clicks into place.
7 Close the finisher front cover.
Note • If the front cover is not completely closed, a message will appear and the machine will
remain paused.
Replacing Fusing Unit
When the fusing unit is near or reaches the end of its life, the following messages are
displayed on the touch screen. Follow the messages.
Message Remaining Page Yield Solution
Consumables need to be
ordered.
Press Machine Status
button and select the
Supplies tab for details.
Approx. 20,000 pages Order the fusing unit.
Consumables need to be
replaced.
Press Machine Status
button and select the
Supplies tab for details.
-
Replace the fusing unit with a
new one.