- 68 - eBike II, eBike II L, eBike II EL 2018112-069 Rev. F
Mount the calibration weight (8kg) to the hook at the
bottom of the ergometer.
The actual strain gauge voltage (DMS-Volt) is shown and
should be in the given range.
SET stores the GAIN value
ATTENTION: The storage of the value needs
some seconds!
The successfull calibration is conrmed.
Remove the calibration weight.
Leave the menu by pressing ESC (top right key).
Static load calibration finiShed
Static Load Calibration
DMS-Volt: 1676 mV
Calibr. succesfull
8 Kg calibration weight
calibration weight Mounted (8 Kg)