7.3.4  Installing the Brass Adapter onto the Valve 
Cover the adaptor’s threads with PTFE tape (see Figure 7-4 below). 
 
Use only PTFE tape to seal the threads of both the adapter and 
the  Hydran  201  sensor.  Wrap  at  least  4  to  5  layers  of  tape 
around the threads.  
Always wrap the tape counter to the treads. 
 
Figure 7-4: Wrap the Adapter and Sensor Threads with PTFE Tape 
 
1.  Screw the adaptor onto the valve and tighten it using a pipe wrench.  Ensure two 
of the screw holes of the adaptor (used to fasten the Hydran 201Ti’s heating plate) 
are level (horizontal); see Figure 7-5 below. 
The H201Ti can be installed either on a horizontal 
(recommended) or vertical valve.  If installed vertically, read the 
points listed in section 6.2.2. 
 
 
Figure 7-5: Ensure that Two Screw Holes are Horizontal