MA-033 Rev. 14.0, 12-Nov-18
Hydran* 201i Instruction Manual
Page 194
14.2 Replacing the Fuse
In case the fuse of the Hydran 201Ti has blown off, remove the fuse holder and
replace the fuse.
The replacement of the fuse must be executed by trained
service personnel only.
Fuse specifications:
- GE part number: 17225
- Fuse size: 5 x 20 mm
- Fuse type: Time delay
- Fuse rating: 5A, 250V
- Recommended models: 0218005.MXP (Littelfuse)
14.3 Replacing the Battery
Refer to section 3.7.4.
14.4 Periodic Maintenance
The person in charge of maintenance must already be familiar enough with the
Hydran 201i System to:
Use and set the Hydran 201Ti’s parameters with its keypad.
Use the Hydran 201Ci Controller and communicate with it.
Use General Electric Canada’s Hydran Host software.
If not, reviewing the previous chapters helps in performing maintenance routines.
Also, consult the Hydran Host Software Manual.
Table 14-1 below summarizes the maintenance routines and their frequency. Each
routine is explained in detail in the Section indicated in the table.