Table D - 2: Alarm Contacts 9 Terminal Block and J5 Connector
Voltage Selector
a
Voltage Range
Comment
115V
100120 VAC, 50/60 Hz
430 W maximum heating
@ 264 VAC
230V
200240 VAC,
50/60 Hz
a: The voltage selector is factory-selected and configured as per user requirements
Table D - 3: SW1 Voltage Selector
Terminal
Description
To (Internal)
From
(External)
Comments
J2-1 and J2-5
Heater A
Power board
Heating plate
Heater
resistance:
81 Ω (each)
J2-4 and J2-6
Heater B
J2-2 and J2-3
Thermostat
Thermostat
Table D - 4: J2 Heater 6 pin Connector
Terminal
Description
To (Internal)
From (External)
J1-4
Sensor cell (+)
Cell amplifier
Sensor cable (black)
J1-3
Sensor cell (-)
Sensor cable (brown)
J1-2
Sensor thermistor
Sensor thermistor
amplifier
Sensor cable (white)
J1-1
Cable shield
I/O module chassis
Not connected
J2-1
Heater thermistor
Heater thermistor
amplifier
Heating plate
thermistor
J2-2
Cable shield
I/O module chassis
Not connected
Table D - 5: J1 Sensor 4 Pin Connector and J2 Thermistor 2 Pin Connector-