MA-033 Rev. 14.0, 12-Nov-18
Hydran* 201i Instruction Manual
Page 230
Voltage Selector
a
Voltage Range
Comment
115V
100120 VAC 50/60 Hz
130W maximum heating
@ 264 VAC
230V
200240 VAC 50/60 Hz
a: The voltage selector is factory-selected and configured as per user requirements
Table D - 12: SW1 Voltage Selector for the Hydran 201Ci-1
Terminal
Name
Direction
Comments
2
RxD
(receives data)
To H201Ci
The DB-9 connector is
wired as in a PC: Cross
wires 2 and 3 when
connecting to a PC; do
not cross wires 2 & 3
when attaching a
modem. Only wires 2, 3
and 5 are needed to
communicate.
3
TxD
(transmits data)
From H201Ci
5
GND (signal ground)
1,4,6,9
DCD, DTR, DSR & RI wired together
7,8
RTS & CTS wired together
Table D - 13: DB-9 Male RS-232 Connector for the Hydran 201Ci-1
Figure D - 3: Wiring of RS-485 Link Cable Between Two or More H201Ci-Cs and H201Ci-1s
Note: The cable shield must be connected to the enclosure ground at only one end.