3.9.1 European wind regions
The operating company is responsible
for applying the correct wind region.
Local conditions such as:
mountains, bays, valleys,
house gullies, thoroughfares,
buildings, etc.
can create wind turbulences and make
it necessary to apply another wind re-
gion.
Assembly
height
metres
Wind pressures by
region (N/m²)
A/B C D E
0 – 10 544 741 968 1225
10 – 20 627 853 1114 1410
20 – 50 757 1031 1347 1704