EasyManua.ls Logo

GEDA 300Z - 18.2 Maintenance plan

Default Icon
101 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GEDA
®
300 Z / ZP
Page 83 of 101 Rev.: 001
BL 121 EN Translation of the original operating manual 2011 / 05
18.2 Maintenance plan
Tasks to be carried out
Quarterly Every
year
Function test of the car control X
Function test of the car control
X
Check notices are present X
Check the gear rack and drive pinion for wear X
Check / refill the lubrication facility X
Check the trailing cable for damage X
Check collision grille and roof X
Check the gear rack is positioned securely
X
Check attachment bolts on the access to the car
(mounting frame) and tighten if necessary.
X
Check motor brakes (air gap and pad thickness)
X
Test / adjust the rescue equipment (release motor brakes)
X
Test the safety gear
X
Check track rollers on the sliding carriage
X
Protective earth testing in accordance with EN 60204, part 1
X
Insulation test in accordance with EN 60204, part 1
X
Visual check of all control devices, limit switches and lines
X
DANGER
Electric shock
Parts remain live even after actuating the
EMERGENCY STOP or after switching off the
machine at the master switch.
Applies to all work on electrical parts.
Disconnect mains supply upstream from the
master switch.
WARNING
Danger to life
Raised load.
Do not stand under a suspended load.
Do not stand on a suspended load.
Only lift loads at the suspension points.
Only use suitable hoisting gear.
WARNING
Danger to life
Access only for authorised individuals.
No access for unauthorised individuals.

Table of Contents