BL 121 EN Translation of the original operating manual 2011 / 05
Documenting the results
The operating company must document the results of inspections. The
documentation must be kept for a reasonable period of time – however at
least for the entire lifetime of the machine. Proof of performance of the last
inspection must be attached to the machine.
18.4 Visual inspections
Entire machine
Damaged load-bearing elements / deformations.
Travel path of the machine clear.
Loose or fallen parts.
Damage to the car.
Oil / grease leaks.
Discolourations and soiling, corrosion, cracks.
Operation control light is on.
Warning and instruction notices
All present and legible.
Safety equipment
All present.
Functional.
No tampering.
Switch cabinets
Burnt / scorched areas.
Discolourations.
Moisture.