EasyManua.ls Logo

GEDA 300Z - 10.1 EMERGENCY STOP; 10.2 Triggering an EMERGENCY STOP; machine shut-down in events of emergency; 10.3 Ending the EMERGENCY STOP situation; 10.4 Defect after an EMERGENCY STOP situation

Default Icon
101 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GEDA
®
300 Z / ZP
Page 52 of 101 Rev.: 001
BL 121 EN Translation of the original operating manual 2011 / 05
10.1 EMERGENCY STOP
Press EMERGENCY STOP only in an emergency.
The machine has 3 EMERGENCY STOPs:
Car control
Manual control
Drop-test control unit
10.2 Triggering an EMERGENCY STOP / machine shut-down in
events of emergency
Push in the EMERGENCY STOP by hand.
10.3 Ending the EMERGENCY STOP situation
Pull EMERGENCY STOP out.
10.4 Defect after an EMERGENCY STOP situation
If an EMERGENCY STOP situation cannot be cancelled, the machine
must be turned off at the master switch and secured against unauthorised
switch-on until it is repaired. The superior must be informed.
DANGER
Electric shock
Parts remain live even after actuating the
EMERGENCY STOP or after switching off the
machine at the master switch.
Applies to all work on electrical parts.
Disconnect mains supply upstream from the
master switch.
DANGER
Danger to life
Due to the machine being switched on during
servicing / repair work or after a defect.
Secure master switch with a padlock to prevent
it from being switched on.

Table of Contents

Related product manuals