3.9.7 Tests
The following tests have been carried out prior to delivery:
Dynamic test of the safety gear with 1.25 times the maximum load
capacity by means of a drop test.
Electrical tests according to EN 60204.
Function tests.
3.9.8 Operating and environmental conditions
The machine may only be operated when the following operating and
environmental conditions are satisfied:
Temperature range: minimum −20 °C
maximum +40 °C
Wind speed:
Operation / maintenance / servicing maximum 72 km/h
Installation maximum 45 km/h
Weather conditions:
No storms with risk of lightning.
It may be necessary to cease / prohibit operation of the machine under ex-
treme weather conditions, even if the operating and environmental condi-
tions fall within the bounds of those stated. For example, due to the paral-
lel occurrence of extreme frost and storms. The operating company must
provide appropriate precautions in this regard.
Atmosphere:
Transporting people:
The composition of the atmosphere must be suitable for people remaining
in this area. Any reduction in the oxygen concentration as a result of dis-
placement or consumption must in particular be prevented. The legal limit
values for pollutant concentrations / aerosols and dust in the workplace
must not be exceeded.
Material transport:
When transporting material, this must not lead to a concentration of abra-
sive / corrosive substances and of explosive fine particulate matter. If this
cannot be excluded with certainty, then the corrosion protection and / or
the functional reliability of the electrical components must be inspected at
regular intervals and if necessary replaced. Fine particulate matter must
be removed.