18.7.4 Check safety gear for damage
If any damage is identified on the safety gear, the safety gear must be re-
placed immediately. Machine operation is prohibited until it is repaired.
18.7.5 Safety gear replacement
GEDA safety gear must be replaced with new GEDA safety gear (safety
gear exchange units) after 5 years at the latest.
The obligation to replace safety gear applies to both material hoists and
personnel hoists.
WARNING
Risk of injury
The safety gear must be inspected every 5 years by the manu-
facturer. Repairs must only be carried out by the manufacturer.
Turn the master switch to the OFF position.
Secure against being switched on.
Loosen nut (1).
Remove protective cover (2).
Test brake pads for damage.
Test flyweights for ease of movement.
Condition of welded seams.
Condition of springs.
Corrosion / deformation.
Put back protective cover.
Mount protective cover (2) in such a way that
switch tag (3) engages in the slot on the protec-
tive cover. (Alternatively, turn the protective cov-
er anti-clockwise until the switch tag (3) engages
in the slot on the protective cover.)
Tighten nut (1).
1
3
2