3-80
CHAPTER 3 Settings and Measurement
•
Relay Capture Function
< Relay capture >
(1)
(2)
(3)
(4)
Setting Description
(1) Ring/Relay capture Set the capturing function.
off: Capturing function is not used.
Ring: Ring capture is performed. (For details, refer to the gure below.)
Relay: Data is captured consecutively for each le of up to 4GB continuously.
When the ring and relay functions are enabled,available sampling interval starts from 10 ms
when the CSV le format is set.
(2) Relay mode Set the mode for performing the relay processing.
Time: After the set time has elapsed, the relay processing is performed.
Capacity: When the le has reached the set le size, relay processing is performed.
(3) Relay time Set the relay time when relay mode is set to "Time".
0 hour 1 minute to 24 hours 00 minutes
* If the le size reaches 4GB before the set time elapses, the relay processing is performed
even before the time elapses.
(4) Relay capacity Set the le size when relay mode is set to "Capacity".
10MB to 4000MB
* Estimated time for capturing with the set le size is displayed as "Relay time".
The recorded data is continuously captured by les separated in the set relay unit without losing data.
(The maximum capacity for a single le is 4GB.)