Caution: rotation
Please note that the rewinder will begin to rotate as soon as the voltage is applied if no backing paper is inserted
at this moment. This rotation will stop automatically after a short time.
Time the button is
pressed
Action/Function
< 3s
1. Switches on the unit if it is currently switched off.
2. Resets the unit if an error is pending (indicated by flashing code, see below).
> 3s and < 10s Switch the unit off
The “Settings – Retooling the Product” section describes the settings you can make on this unit.
Error codes
Error codes, i.e. flashing codes, can be acknowledged and reset by briefly pressing the illuminated button. The
following codes are possible:
Flashes Cause
5x Measurement error during teach-in of the angle sensor (see above)
8x
The pendulum remains in the rest position too long. Possible web break or the rewinder is
not winding fast enough.
9x Voltage in power supply unit too low.
10x Continuous overload of the drive. The power consumption is too high.
11x Drive temperature too high.
13x Diameter determination failed (only for CAN connection).