Documentation HERMA 500
1.10 GB (2019/02/28)
27
Time the button is
pressed
Action/Function
< 3s
1. Switches on the unit if it is currently switched off.
2. Resets the unit if an error is pending (indicated by flashing code, see below).
> 3s and < 10s Switch the unit off
The “Settings – Retooling the Product” section describes the settings you can make on this unit.
Error codes
Error codes, i.e. flashing codes, can be acknowledged and reset by briefly pressing the illuminated button. The
following codes are possible:
Flashes Cause
8x
Loop formation is taking too long (web break, drive roller is tangled, removal rate is too
high).
9x Voltage in power supply unit too low.
10x Continuous overload of drive. Power consumption is too high.
11x Drive temperature too high.