Technical data
42 1.10 GB (2019/02/28)
Technical data
Technical data
The HERMA 500 applicators leave our factory with tested functionality and are ready for operation with default
settings.
The following specifications refer to the applicator’s drive unit.
Model versions
“IO” for I/O applicators, “IE” for industrial Ethernet applicators. (See the type plate of the
basic unit.)
Mains voltage
Wide range input
100V AC – 240V AC ±10%,
50Hz – 60Hz
Max. power consumption
400W + n * 100W (n = number of motorised winder units)
Leakage current according to EN 60335-1
110V AC: < 0.35mA
150V AC: < 0.5mA
230V AC: < 0.7mA
Fuses in the applicator
2 x T3,15 A type TR5