Documentation HERMA 500
1.10 GB (2019/02/28)
25
Error codes
Error codes, i.e. flashing codes, can be acknowledged and reset by briefly pressing the illuminated button. The
following codes are possible:
Flashes Cause
5x
Measurement error during teach-in of the angle sensor (see “Teaching in the Angle Sensor
(Motorised Unwinder)”)
8x
The pendulum remains in its maximum deflection position for too long. The core sleeve
may be insufficiently tensioned, the web may be depleted but stuck to the sleeve, or the
motor may be faulty.
9x Voltage in power supply unit too low.
10x Continuous overload of the drive. The power consumption is too high.
11x Drive temperature too high.
12x End of reel reported.
13x Diameter determination failed (only for CAN connection).
Loop Module: Motorised
Inserting the Label Web
Insert the label reel such that the labels reach the dispensing beak in the correct position.
Insert the label web according to the diagrams contained in the “Label Web Threading Diagram”
section.
Switch the unit on and off using the switch / illuminated button a.
To thread the label web with motor assistance (recommended), proceed as follows (loop module must be
switched off):