ID2000 Series Industrial Code Reader User Manual
80
Stop Trigger via Serial Port
When the specified serial port receives the specified string text, the trigger will be stopped.
Steps
1. Go to I/O Control Settings Stop Trigger.
2. Enable Serial Stop Trigger Enable.
3. Set following parameters according to actual demands.
Serial Stop Trigger Text: It sets the trigger text of serial port stop, and it is Stop by default.
Serial Baud Rate: It sets the baud rate of the serial port, and it is 9600 by default.
Serial Data Bits: It sets the data bits of the serial port, and it is 8 by default.
Serial Parity: It sets the parity of the serial port, and it is No Parity by default.
Serial Stop Bits: It sets the stop bits of the serial port, and it is 1 by default.
Stop Trigger via USB
The USB stop trigger function means that the device receives USB commands from the
external device to stop image acquisition. At this time, the device acts as a USB server to
receive commands, and the external device communicating with it acts as a USB client to
send commands.
Go to Feature Tree, find Stop Trigger Control, enable USB Stop Trigger Enable, set USB Stop
Trigger Text, USB Baudrate, USB Data Bits, USB Parity, and USB Stop Bits according to
actual demands.
Figure 9-33 Stop Trigger via USB
Stop Trigger via Timeout Duration
When the trigger time reaches the specified maximum value (ms), the trigger will be stopped.
You can enable TimeOut Stop Trigger Enable, and set Maximum Output Limited Time

Table of Contents