9.6 Message List
120
Message Data Contents Description
Ref
page
Reading Measured Values
:FETCh?
[<measurement value>]
Reads the most recent measurement. 141
:READ?
[<measurement value>]
Waits for trigger and reads the mea-
sured value.
141
Memory Function
:MEMory:MODE
OFF/ MEMory/ AUTO
Sets and queries the memory mode. 142
:MEMory:MODE?
[OFF/ MEMORY/ AUTO]
:MEMory:CLEar
Clears memory data. 142
:MEMory:COUNt?
[0 to 30000]
Queries the number of measurements
stored in memory.
142
:MEMory:DATA?
[<Measurement value>,
<measurement value>,
...,<measurement value>]
Reads the measurements stored in
memory.
143
:MEMory:POINt
1 to 30000
Sets and queries the number of mea-
surement points to store.
143
:MEMory:POINt?
[1 to 30000]
Range-Specific Resistance Measurement Settings
:RESistance:DELay2
<Range>,<Delay 2 time>
Sets and queries Delay 2. 144
:RESistance:DELay2?
<Range>
[0 to 0.100]
:RESistance:NPLCycles
<Range>,<Speed>,
<Integration time (NPLC)>
Sets and queries integration time (no.
of power line cycles).
144
:RESistance:NPLCycles?
<Range>,<Speed>
[0.01 to 6]
:RESistance:APERture
<Range>,<Speed>,
<Integration time (s)>
Sets and queries integration time (in
seconds).
145
:RESistance:APERture?
<Range>,<Speed>
[0.0001 to 0.1]
:RESistance:CIMProve
<Range>,<OFF/ HOLD/
PULSe>
Sets and queries Contact Improver op-
erating mode.
145
:RESistance:CIMProve?
<Range>
[OFF/ HOLD/ PULSE]
:RESistance:CIMProve:LEVel
<Range>,<Level>
Sets and queries Contact Improver
level.
145
:RESistance:CIMProve:LEVel?
<Range>
[L1/ L2/ L3/ L4]
:RESistance:CURRent
<Range>,<PULSe/ CON-
Tinuous>
Sets and queries measurement cur-
rent mode.
146
:RESistance:CURRent?
<Range>
[PULSE/ CONTINUOUS]
:RESistance:CONTactcheck
<Range>,<1/ 0/ ON/ OFF>
Sets and queries contact check opera-
tion.
146
:RESistance:CONTactcheck?
<Range>
[ON/ OFF]
:RESistance:CONTactcheck:LEVel
<Range>,<Level>
Sets and queries contact check
threshold.
147
:RESistance:CONTactcheck:LEVel?
<Range>
[L1/ L2/ L3/ L4/ L5/ L6/ L7]
:RESistance:VMONitor
<Range>,<1/ 0/ ON/ OFF>
Sets and queries voltage level monitor
operation.
147
:RESistance:VMONitor?
<Range>
[ON/ OFF]
:RESistance:VMONitor:LEVel
<Range>,<Level>
Sets and queries voltage level monitor
level.
147
:RESistance:VMONitor:LEVel?
<Range>
[L1/ L2/ L3]
Notes:
• < >: contents of the data portion.
• [ ]: Response data
• <Range>
For
:RESistance commands: RNG100MIL/ RNG1000MIL/ RNG10/ RNG100/ RNG1000/ RNG10K/ RNG100K/
RNG1000K/ RNG10MEG/ RNG100MEG
For :LPResistance commands: RNG1000MIL/ RNG10/ RNG100/ RNG1000