8.7 Command Message Description
206
Example
Command
:CONFigure:AUTO ON;:CONFigure:WTIMe:POLarity0 10
Sets the wait time (delay b1) for switching operation in automatic measurement
to 10 seconds.
Query
Response
:CONFigure:WTIMe:POLarity0?
:CONFIGURE:WTIME:POLARITY0 1200 (Headers : ON)
1200 (Headers : OFF)
The wait time (delay b1) for switching operation in automatic measurement has
been set to 1,200 seconds.
Error
An execution error occurs in the following cases :
When the measurement method is set to "manual measurement"
When the measurement mode is not selected
When a mode other than "leakage current mode" is set
In automatic measurement (Command)
When a value outside the specified range is input
Note
Use this command after executing the :MODE command to activate the mea-
surement mode.
The unit is [s]. Fractions are rounded up when 0.5 or greater and rounded off
when less than 0.5.
Sets and queries the wait time for switching operation in automatic measure-
ment (delay b1)
Sets and queries the grounding class of equipment under test
Syntax
Command
Query
Response
:EQUipment <characters>
:EQUipment?
<characters>
<characters> = CLAss1(CLA1)/ CLAss2(CLA2)/ INTernal
CLAss1 : Class-I equipment
CLAss2 : Class-II equipment
INTernal: Internally powered equipment
Function
Command Sets the grounding class of equipment under test.
Query Returns the grounding class setting of equipment under test as alphabetic char-
acters.
Example
Command
:MODE OFF;:EQUipment CLAss1
Sets the grounding class of equipment under test to "Class-I equipment."
Query
Response
:EQUipment?
:EQUIPMENT CLASS1 (Headers : ON)
CLASS1 (Headers : OFF)
The grounding class of equipment under test has been set to "Class-I equip-
ment."
Error
An execution error occurs in the following cases:
When the measurement mode is selected (Command)
When a mode other than "leakage current mode" is set (Command)