EasyManua.ls Logo

Hioki ST5540 - Other Test Condition and Special Test Condition

Hioki ST5540
326 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix2 List of instrument status, other test condition and special test condition
A4
When network A, D, E or F is selected
When network B1 is selected
Appendix2 List of instrument status, other test
condition and special test condition
Measurement
mode
Class-I equipment Class-II equipment Internally powered equipment
Equipment status Equipment status Equipment status
Normal
condi-
tion
Single-fault condition
Normal
condi-
tion
Single-fault condition
Normal
condi-
tion
Single-fault condition
Power
cord dis-
connec-
tion
Ground-
ing wire
discon-
nection
Applica-
tion of
line volt-
age L
Applica-
tion of
line volt-
age N
Power
cord dis-
connec-
tion
Ground-
ing wire
discon-
nection
Applica-
tion of
line volt-
age L
Applica-
tion of
line volt-
age N
Power
cord dis-
connec-
tion
Ground-
ing wire
discon-
nection
Applica-
tion of
line volt-
age L
Applica-
tion of
line volt-
age N
Earth leakage
current
 –––––––––––
Enclosure -
Line leakage
current
––––––
Enclosure -
Earth leakage
current
 –– ––– ––––
Enclosure -
Enclosure
current
 –– ––– ––––
Free current*

––
 ––– ––––
*Only network A
:Can be set, –:Cannot be set
Measure-
ment
mode
Class-I equipment Class-II equipment Internally powered equipment
Equipment status Equipment status Equipment status
Normal
condition
Single-fault condition
Normal
condition
Single-fault condition
Normal
condition
Single-fault condition
Power
cord dis-
connec-
tion
Ground-
ing wire
discon-
nection
Applica-
tion of
110%
voltage
: Positive
phase
Applica-
tion of
110%
voltage
: Nega-
tive
phase
Power
cord dis-
connec-
tion
Ground-
ing wire
discon-
nection
Applica-
tion of
110%
voltage
: Positive
phase
Applica-
tion of
110%
voltage
: Nega-
tive
phase
Power
cord dis-
connec-
tion
Ground-
ing wire
discon-
nection
Applica-
tion of
110%
voltage
: Positive
phase
Applica-
tion of
110%
voltage
:Nega-
tive
phase
Earth
leakage
current

–– –– ––
Enclosure
- Earth
leakage
current


––

Enclosure
- Enclo-
sure
current


––

Patient
auxiliary
current

––

––
––
Patient
leakage
current I

––

––
––
Patient
leakage
current
II(only
B-type ap-
plied parts)
––

––

––

Patient
leakage
current
III(only BF-
type or CF-
type ap-
plied parts)
––

––

––

Free
current


––

:Can be set, –:Cannot be set

Table of Contents

Related product manuals