Appendix2 List of instrument status, other test condition and special test condition
A6
When network B2 is selected
1:Earth leakage current, 2:Touch current:Enclosure - Earth, 3:Touch current:Enclosure - Enclosure, 4:Patient auxiliary current, 5:Patient leakage current:(Patient - Earth),
6:Patient leakage current:SIP/SOP, 7:Patient leakage current: F-typeApplied part(only BF-type or CF-type applied parts),8:Patient leakage current:Metal accessible part(only B-type
or BF-type applied parts), 9:Total patient leakage current:(Patient - Earth), 10:Total patient leakage current:SIP/SOP,11:Total patient leakage current:F-type applied part(only BF-type
or CF-type applied parts), 12:Total patient leakage current:Metal accessible part(only B-type or BF-type applied parts), 13:Free current
Measurement mode
Class-I
equipment
Class-II
equipment
Internally
powered
equipment
Equipment
status
Other test condition
(Other applied voltages)
Special test condition
(Specific applied voltage)
Equipment
status
Other test condition
(Other applied voltages)
Special test condition
(Specific applied voltage)
Equipment
status
Other test condition
(Other applied voltages)
Special test condition
(Specific applied voltage)
Normal condition
Single-
fault
condition
Normal condition
Single-
fault
condition
Normal condition
Single-
fault
condition
Power cord disconnection
Grounding wire
disconnection
Application of 110%
voltage:Positive phase
Application of 110%
voltage:Negative phase
Application of 110%
voltage:Positive phase
Application of 110%
voltage:Negative phase
Application of 110%
voltage:Positive phase
Application of 110%
voltage:Negative phase
Power cord disconnection
Grounding wire
disconnection
Application of 110%
voltage:Positive phase
Application of 110%
voltage:Negative phase
Application of 110%
voltage:Positive phase
Application of 110%
voltage:Negative phase
Application of 110%
voltage:Positive phase
Application of 110%
voltage:Negative phase
Power cord disconnection
Grounding wire
disconnection
Application of 110%
voltage:Positive phase
Application of 110%
voltage:Negative phase
Application of 110%
voltage:Positive phase
Application of 110%
voltage:Negative phase
Application of 110%
voltage:Positive phase
Application of 110%
voltage:Negative phase
1
––––– –––––
––––
2
 ––  –– 
––
3
 ––  –– 
––
4
––––– –––––
––––
5
––––– –––––
––––
6
 ––  –– 
––
7
––– –––
––

8
––– –––
––

9
––––– –––––
––––
10
 ––  –– 
––
11
––– –––
––

12
––– –––
––

13
 ––  –– 
––
:Can be set, –:Cannot be set

Table of Contents

Related product manuals