E1 Series Servo Drive User Manual Parameters
15-48 HIWIN MIKROSYSTEM CORP.
MD09UE01-1910
Pt No.
Pt702
Size 2
Setting
Range
0~3000 Default 6
Name
Velocity for finding
home position
(rotary servo motor)
Unit 1 rpm
Applicable
Motor
Rotary
Effective
Immediately
Category
Setup
Reference
-
Pt No.
Pt703
Size 2
Setting
Range
0~100 Default 20
Name
Time limit for homing
procedure
Unit Second
Applicable
Motor
All
Effective
Immediately
Category
Setup
Reference
-
Pt No.
Pt704
Size 4
Setting
Range
-1073741824
1073741824
Default 0
Name Home offset Unit 1 control unit
Applicable
Motor
All
Effective
Immediately
Category
Setup
Reference
-
Pt No.
Pt705
Size 2
Setting
Range
0~1000 Default 10
Name
Velocity for finding
near home sensor
(linear servo motor)
Unit 1 mm/s
Applicable
Motor
Linear
Effective
Immediately
Category
Setup
Reference
-
Pt No.
Pt706
Size 2
Setting
Range
0~1000 Default 3
Name
Velocity for finding
home position (linear
servo motor)
Unit 1 mm/s
Applicable
Motor
Linear
Effective
Immediately
Category
Setup
Reference
-
Pt No.
Pt707
Size 2
Setting
Range
2~10000 Default 100
Name
Homing acceleration
time
Unit 1 ms
Applicable
Motor
All
Effective
Immediately
Category
Setup
Reference
-