Item
Number
Item Description NX-19 AGA-8 Gross
Method1
AGA-Gross
Method2
AGA-8
Detail
390 % N-Decane
ü
391 % Water
ü
34 Base Temperature
ü ü ü ü
13 Base Pressure
ü ü ü ü
26 Flow Temperature*
ü ü ü ü
8 Flow Pressure*
ü ü ü ü
1161 Fixed Pressure Value*
ü ü ü ü
1162 Fixed Temperature
Value*
ü ü ü ü
Note: (*) Items 8 and 26 are live readings (not user configurable). They are used for
supercompressibility calculations when pressure and/or temperature calculations are “live” per items
109 and 111, respectively. If pressure and/or temperature is fixed, items 1161 and/or 1162 (user
configurable fixed pressure and fixed temperature values, respectively) are used instead of items 8
and/or 26 in supercompressibility calculations.