71
View
HWTACACS scheme view
Default level
2: System level
Parameters
data { byte | giga-byte | kilo-byte | mega-byte }: Specifies the unit for data flows, which can be byte,
kilobyte, megabyte, or gigabyte.
packet { giga-packet | kilo-packet | mega-packet | one-packet }: Specifies the unit for data packets,
which can be one-packet, kilo-packet, mega-packet, or giga-packet.
Description
Use the data-flow-format command to set the traffic statistics unit for data flows or packets.
Use the undo data-flow-format command to restore the default.
By default, the unit for data flows is byte and that for data packets is one-packet.
Related commands: display hwtacacs.
Examples
# Set the traffic statistics unit for data flows and that for packets to kilobytes and kilo-packets respectively
in HWTACACS scheme hwt1.
<Sysname> system-view
[Sysname] hwtacacs scheme hwt1
[Sysname-hwtacacs-hwt1] data-flow-format data kilo-byte packet kilo-packet
display hwtacacs
Syntax
display hwtacacs [ hwtacacs-scheme-name [ statistics ] ] [ slot slot-number ] [ | { begin | exclude |
include } regular-expression ]
View
Any view
Default level
2: System level
Parameters
hwtacacs-scheme-name: HWTACACS scheme name.
statistics: Displays detailed statistics about the HWTACACS server.
slot slot-number: Specifies the member number of the device in the IRF virtual device, which you can
display with the display irf command. The value range for the slot-number argument depends on the
number of members and numbering conditions in the current IRF virtual device. If no IRF virtual device
exists, the slot-number argument is the current device number.
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see the Fundamentals Configuration Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.