Configuring Port-Based and User-Based Access Control (802.1X)
Configuring Switch Ports as 802.1X Authenticators
[reauth-period < 0 - 9999999 >]
Sets the period of time after which clients connected
must be re-authenticated. When the timeout is set to 0
the reauthentication is disabled (Default: 0 second)
[unauth-vid < vlan-id >]
Configures an existing static VLAN to be the Unautho-
rized-Client VLAN. This enables you to provide a path
for clients without supplicant software to download the
software and begin an authentication session. Refer to
“802.1X Open VLAN Mode” on page 12-31.
aaa port-access authenticator < port-list >
[logoff-period]< 1 - 999999999 >
Configures the period of time the switch waits for
client activity before removing an inactive client from
the port. (Default: 300 seconds)
[unauth-period < 0-255 >]
Specifies a delay in seconds for placing a port on the
Unauthorized-Client VLAN. This delay allows more
time for a client with 802.1X supplicant capability to
initiate an authentication session. If a connected cli-
ent does not initiate a session before the timer expires,
the port is assigned to the Unauthenticated-Client
VLAN. (Default: 0 seconds)
[auth-vid < vid >]
Configures an existing, static VLAN to be the Autho-
rized-Client VLAN. Refer to “802.1X Open VLAN Mode”
on page 12-31.
12-25

Table of Contents

Other manuals for HP PROCURVE 2910AL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP PROCURVE 2910AL and is the answer not in the manual?

HP PROCURVE 2910AL Specifications

General IconGeneral
ModelHP ProCurve 2910al
Switching Capacity128 Gbps
Throughput95.2 Mpps
ManagementWeb, CLI, SNMP
Jumbo Frame SupportYes
ManageableYes
Power100-240 VAC
Power SupplyInternal
Operating Temperature0°C to 45°C (32°F to 113°F)
StackingYes
MAC Address Table Size32000 entries
Routing ProtocolRIP, OSPF
FeaturesIPv6, VLAN, QoS, ACLs
Operating Humidity15% to 95% non-condensing
Uplink Ports4
Power over EthernetYes (PoE+ models available)

Related product manuals