Configuring and Monitoring Port Security
Reading Intrusion Alerts and Resetting Alert Flags
Figure 13-12. Example of Multiple Intrusion Log Entries for the Same Port
The log shows the most recent intrusion at the top of the listing. You cannot
delete Intrusion Log entries (unless you reset the switch to its factory-default
configuration). Instead, if the log is filled when the switch detects a new
intrusion, the oldest entry is dropped off the listing and the newest entry
appears at the top of the listing.
Keeping the Intrusion Log Current by Resetting Alert
Flags
When a violation occurs on a port, an alert flag is set for that port and the
violation is entered in the Intrusion Log. The switch can detect and handle
subsequent intrusions on that port, but will not log another intrusion on the
port until you reset the alert flag for either all ports or for the individual port.
On a given port, if the intrusion action is to send an SNMP trap and then disable
the port (send-disable), and an intruder is detected on the port, then the switch
sends an SNMP trap, sets the port’s alert flag, and disables the port. If you re-
enable the port without resetting the ports alert flag, then the port operates
as follows:
The port comes up and will block traffic from unauthorized devices it
detects.
If the port detects another intruder, it will send another SNMP trap, but
will not become disabled again unless you first reset the port’s intrusion
flag.
This operation enables the port to continue passing traffic for authorized
devices while you take the time to locate and eliminate the intruder. Other-
wise, the presence of an intruder could cause the switch to repeatedly disable
the port.
Note on
Send-Disable
Operation
13-35

Table of Contents

Other manuals for HP PROCURVE 2910AL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP PROCURVE 2910AL and is the answer not in the manual?

HP PROCURVE 2910AL Specifications

General IconGeneral
ModelHP ProCurve 2910al
Switching Capacity128 Gbps
Throughput95.2 Mpps
ManagementWeb, CLI, SNMP
Jumbo Frame SupportYes
ManageableYes
Power100-240 VAC
Power SupplyInternal
Operating Temperature0°C to 45°C (32°F to 113°F)
StackingYes
MAC Address Table Size32000 entries
Routing ProtocolRIP, OSPF
FeaturesIPv6, VLAN, QoS, ACLs
Operating Humidity15% to 95% non-condensing
Uplink Ports4
Power over EthernetYes (PoE+ models available)

Related product manuals