EasyManuals Logo

HP PROCURVE 2910AL User Manual

HP PROCURVE 2910AL
594 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #131 background imageLoading...
Page #131 background image
TACACS+ Authentication
General System Requirements
General System Requirements
To use TACACS+ authentication, you need the following:
A TACACS+ server application installed and configured on one or more
servers or management stations in your network. (There are several
TACACS+ software packages available.)
A switch configured for TACACS+ authentication, with access to one or
more TACACS+ servers.
Notes The effectiveness of TACACS+ security depends on correctly using your
TACACS+ server application. For this reason, ProCurve recommends that you
thoroughly test all TACACS+ configurations used in your network.
TACACS-aware ProCurve switches include the capability of configuring
multiple backup TACACS+ servers. ProCurve recommends that you use a
TACACS+ server application that supports a redundant backup installation.
This allows you to configure the switch to use a backup TACACS+ server if it
loses access to the first-choice TACACS+ server.
TACACS+ does not affect web browser interface access. Refer to “Controlling
Web Browser Interface Access When Using TACACS+ Authentication” on
page 4-27.
General Authentication Setup Procedure
It is important to test the TACACS+ service before fully implementing it.
Depending on the process and parameter settings you use to set up and test
TACACS+ authentication in your network, you could accidentally lock all
users, including yourself, out of access to a switch. While recovery is simple,
it may pose an inconvenience that can be avoided.To prevent an unintentional
lockout on the switch, use a procedure that configures and tests TACACS+
protection for one access type (for example, Telnet access), while keeping the
other access type (console, in this case) open in case the Telnet access fails
due to a configuration problem. The following procedure outlines a general
setup procedure.
4-5

Table of Contents

Other manuals for HP PROCURVE 2910AL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP PROCURVE 2910AL and is the answer not in the manual?

HP PROCURVE 2910AL Specifications

General IconGeneral
ModelHP ProCurve 2910al
Switching Capacity128 Gbps
Throughput95.2 Mpps
ManagementWeb, CLI, SNMP
Jumbo Frame SupportYes
ManageableYes
Power100-240 VAC
Power SupplyInternal
Operating Temperature0°C to 45°C (32°F to 113°F)
StackingYes
MAC Address Table Size32000 entries
Routing ProtocolRIP, OSPF
FeaturesIPv6, VLAN, QoS, ACLs
Operating Humidity15% to 95% non-condensing
Uplink Ports4
Power over EthernetYes (PoE+ models available)

Related product manuals