7. From the primary site, execute the YKRESYNC DELTAJNL command for the delta resync pair.
YKQUERY
YKRESYNC DELTAJNL
YKEWAIT GOTO(DUPLEX)
If the command is successful, the status of the Cnt Ac-J Z copy pair on the local site and remote
site automatically changes to the HOLD status (delta resync pair).
Operation is returned to normal.
NOTE: If during operation the status of a delta resync pair changes to HOLDTRNS, NODELTA,
or HOLDER, see Actions to be Taken When the Delta Resync Function Cannot be Set Up or
Operated Successfully” (page 340).