HP XP P9500 - Operating Procedure During an Intermediate Site Storage System Failure (Nonvolatile)

HP XP P9500
608 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7. From the primary site, execute the YKRESYNC SELECT(COND) command for the Continuous
Access Journal Z EXCTG.
YKQUERY
YKRESYNC SELECT(COND)
YKEWAIT GOTO(DUPLEX) NOINVALIDCHECK
Operation is returned to normal.
Operating Procedure During an Intermediate Site Storage System Failure (Nonvolatile)
The preparation and recovery procedures to be performed when a nonvolatile failure occurs in
the intermediate site storage system are the same as the procedures to be performed when a path
failure occurs between the primary site storage system and the intermediate site storage system.
See “Operating Procedure During a Path Failure between the Primary Site Storage System and the
Intermediate Site Storage System (page 424).
Using a 4x4x4 Cascade Configuration 415