EasyManua.ls Logo

HP XP P9500 - Failback

HP XP P9500
608 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4. On the primary host, execute the YKRESYNC DELTAJNL command for Cnt Ac-J Z copy pairs
that are in the HOLD status and that are between the local storage system and the remote
storage system.
YKQUERY
YKRESYNC DELTAJNL
YKEWAIT GOTO(DUPLEX)
5. Start a failure recovery of the primary storage systems.
2DC configuration operations are performed from the local storage system.
Failback
1. Recover the primary storage system failure.
2. Use TPC-R on the primary host to dissolve the Cnt Ac-S copy pairs with the HyperSwap attribute.
3. Use TPC-R on the primary host to reconfigure the paths required for Cnt Ac-S copy pairs with
the HyperSwap attribute.
364 Maintenance and Troubleshooting Operations