Setting Description
Spare Activation Mode Predictive Spare Activation mode
activates a spare drive any time a
member drive within an array reports
a predictive failure.
Failure Spare Activation mode
activates a spare drive when a
member drive within an array fails
using fault tolerance methods to
regenerate the data.
Surface Scan Analysis
Priority
Modifies the amount of delay/idle time
of the controller before surface scan
analysis is resumed.
• 0: Disabled
• 1-30: Idle with delay
• 31: High
Transformation priority (Does not apply to HPE Smart Array
S100i SR Gen10 SW RAID.) Rate at
which requests from the operating
system are processed:
• High: Completes as fast as
possible at the expense of normal
I/O.
• Medium: Completes with some
impact on normal I/O.
• Low: Performs when normal I/O is
not occurring.
Unconfigured physical drive
write cache state
Enables or disables the write cache
on all configured physical drives.
Options are Enabled or Disabled.
3. Click Submit changes.
Modifying advanced controller settings
Procedure
1. From the System Utilities screen, select System Configuration > controller > Configure Controller
Settings > Advanced Controller Settings.
2. In the Advanced Controller Settings screen, modify any of the following settings:
System Utilities main menu options 27