Powermax30 AIR Service Manual 808850 59
5 Troubleshooting and System Tests
External inspection
1. Inspect the exterior of the power supply for damage to the cover and external components, such as the power cord
and plug.
2. Inspect the torch and the torch lead for damage.
3. Inspect the consumables for damage or wear.
4. Repair or replace components as necessary.
Internal inspection
1. Set the power switch to OFF (O), and disconnect the power cord from the power source.
2. Remove the power supply handle and cover. See Remove the power supply cover on page 98.
3. Remove the component barrier. See Remove the component barrier on page 100.
4. Inspect the inside of the power supply:
Power board side: Look for broken or loose wiring connections, burn and char marks, damaged components,
and so on.
Fan side: Check for leaks and loose connections at each pneumatic (air) connection point on the internal
compressor, air filter, and solenoid valve.
5. Repair or replace components as necessary.
Initial resistance check
All resistance values must be taken with the power cord disconnected and all internal power supply wires attached.
Perform the steps in Internal inspection (above) before continuing in this section.
The type of multimeter you use significantly affects the results of the tests in this section. The resistance values in this
manual are intended as a general reference point.
If resistance values indicate a problem based on the range of values provided in this section, isolate the problem by
removing wires attached to the resistance check points or component until the problem is found.
After the problem is located and repaired, see Sequence of operation on page 56 to test the power supply for proper
operation.

Table of Contents

Other manuals for Hypertherm Powermax30 AIR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax30 AIR and is the answer not in the manual?

Hypertherm Powermax30 AIR Specifications

General IconGeneral
Built-in Air CompressorYes
Output Voltage83 VDC
Input Voltage120-240 V
Current Output15–30 A
Cutting ThicknessUp to 10 mm (3/8 in) recommended cut
Gas SupplyBuilt-in air compressor
Operating Temperature-10°C to +40°C (+14°F to +104°F)

Related product manuals