Precautions for Axis Operation with Wireless Connection
Intro-14
Precautions for Axis Operation with Wireless Connection
Data Setter TB-03 (V2.30 or later) can operate the option model code -WL2 ELECYLINDER with
wireless connection. For operation with wireless connection, secure safety by following the
precautions below before use.
The stop switch on Data Setter TB-03 will not function during wireless connection. Prepare a
device / circuit to stop the operation when emergency stop is required.
For axis operation with wireless connection, operation testing (movement to forward and backward
ends, jog operation, inching operation) is possible, but the control device is not designed for
purposes of automatic operation. Construct a mechanical system based on the risks of the
operating environment.
Carry out risk assessment based on the standard/spec requirements of the machinery for
installation. Dangerous operation, such as that requiring an automatic stop when control signals
cannot be received (including disabled communication) is not acceptable.
Stopping axis operation by wireless network cannot be used as a safety feature as defined in EN
ISO 13849-1: 2015. It is also not compliant with Safety Category B or Categories 1 to 4 stated in
EN ISO 13849-1: 2015.