5.2 Maintenance information
5-2
5. Preventive/Predictive Maintenance
5.2 Maintenance information
This section introduces three items that can be configured and managed as maintenance
information.
When the set values are exceeded, a "maintenance warning" is issued and the status display
LEDs flash alternately in red and green.
Even if a "maintenance warning" is generated, the ELECYLINDER will continue to operate without
interruption.
Total travel count
Name Symbol Unit Input range
Default setting
at shipping
Total travel count TMCT times 0 to 999, 999,999
0
(disabled setting)
● When the total travel count exceeds the set value, the user will be
notified with "Maintenance warning 1".
● When "Maintenance warning 1" is output, maintenance is recommended,
such as greasing. Set the target value to a value larger than the present one
and update.
● Setting it to "0 times" will disable this function.
Total travel distance
Name Symbol Unit Input range
Default setting
at shipping
Total travel distance ODOT m 0 to 999, 999,999
0
(disabled setting)
● When the total travel distance exceeds the set value, the user will be notified
with "Maintenance warning 2".
● When "Maintenance warning 2" is output, maintenance is recommended,
such as greasing. Set the target value to a value larger than the present one
and update.
● Setting it to "0m" will disable this function.
● The displayed units can be switched. (m
⇔ km)