5.2 Maintenance information
5-2
5. Preventive/Predictive Maintenance
5.2 Maintenance information
This section introduces three items that can be configured and managed as maintenance
information.
When the set values are exceeded, a "maintenance warning" is issued and the status display
LEDs flash alternately in red and green.
Even if a "maintenance warning" is generated, the ELECYLINDER will continue to operate without
interruption.
Total travel count
Name Symbol Unit Input range
Default setting
at shipping
Total travel count TMCT times 0 to 999, 999,999
0
(disabled setting)
When the total travel count exceeds the set value, the user will be
notified with "Maintenance warning 1".
When "Maintenance warning 1" is output, maintenance is recommended,
such as greasing. Set the target value to a value larger than the present one
and update.
Setting it to "0 times" will disable this function.
Total travel distance
Name Symbol Unit Input range
Default setting
at shipping
Total travel distance ODOT m 0 to 999, 999,999
0
(disabled setting)
When the total travel distance exceeds the set value, the user will be notified
with "Maintenance warning 2".
When "Maintenance warning 2" is output, maintenance is recommended,
such as greasing. Set the target value to a value larger than the present one
and update.
Setting it to "0m" will disable this function.
The displayed units can be switched. (m
km)