415
INTELLIGENT ACTUATOR
Appendix
I/O Parameters
No. Parameter name
Default value
(Reference)
Input range Unit Remarks
292 Port number assigned to
input function selection
009
-1 -1 to 3999
Specify the port number to be assigned to the function of I/O
parameter No. 39, “Input function selection 009.
* If a negative value is set, the function will be assigned to input port
No. 9.
* If “Program number specified for program start” has been specified
for input function selection 009, specify in this parameter an input
port number whose LSB contains the next higher value to the LSB
of the program number specified for program start.
(Main application version 0.64 or later/F-ROM 32-Mbit version only)
293 Port number assigned to
input function selection
010
-1 -1 to 3999
Specify the port number to be assigned to the function of I/O
parameter No. 40, “Input function selection 010.
* If a negative value is set, the function will be assigned to input port
No. 10.
* If “Program number specified for program start” has been specified
for input function selection 010, specify in this parameter an input
port number whose LSB contains the next higher value to the LSB
of the program number specified for program start.
(Main application version 0.64 or later/F-ROM 32-Mbit version only)
294 Port number assigned to
input function selection
011
-1 -1 to 3999
Specify the port number to be assigned to the function of I/O
parameter No. 41, “Input function selection 011.
* If a negative value is set, the function will be assigned to input port
No. 11.
* If “Program number specified for program start” has been specified
for input function selection 011, specify in this parameter an input
port number whose LSB contains the next higher value to the LSB
of the program number specified for program start.
(Main application version 0.64 or later/F-ROM 32-Mbit version only)
295 Port number assigned to
input function selection
0122
-1 -1 to 3999
Specify the port number to be assigned to the function of I/O
parameter No. 42, “Input function selection 012.
* If a negative value is set, the function will be assigned to input port
No. 12.
* If “Program number specified for program start” has been specified
for input function selection 012, specify in this parameter an input
port number whose LSB contains the next higher value to the LSB
of the program number specified for program start.
(Main application version 0.64 or later/F-ROM 32-Mbit version only)
296 Port number assigned to
input function selection
013
-1 -1 to 3999
Specify the port number to be assigned to the function of I/O
parameter No. 43, “Input function selection 013.
* If a negative value is set, the function will be assigned to input port
No. 13.
* If “Program number specified for program start” has been specified
for input function selection 013, specify in this parameter an input
port number whose LSB contains the next higher value to the LSB
of the program number specified for program start.
(Main application version 0.64 or later/F-ROM 32-Mbit version only)
297 Port number assigned to
input function selection
014
-1 -1 to 3999
Specify the port number to be assigned to the function of I/O
parameter No. 44, “Input function selection 014.
* If a negative value is set, the function will be assigned to input port
No. 14.
* If “Program number specified for program start” has been specified
for input function selection 014, specify in this parameter an input
port number whose LSB contains the next higher value to the LSB
of the program number specified for program start.
(Related information: I/O parameter No. 30, “Input function
selection 000”)
(Main application version 0.64 or later/F-ROM 32-Mbit version only)
298 Port number assigned to
input function selection
015
-1 -1 to 3999
Specify the port number to be assigned to the function of I/O
parameter No. 45, “Input function selection 015.
* If a negative value is set, the function will be assigned to input port
No. 15.
(Main application version 0.64 or later/F-ROM 32-Mbit version only)