12-18
12
SET MODE
CI–V Address
74h
Todistinguishequipment,eachCI-Vtransceiverhas
itsownIcomstandardaddressinhexadecimalcode.
The IC-7700’s address is 74h.
When 2 or more IC-7700’s are connected to an op-
tional CT-17 c i -v l e v e l c o n v e r t e r , rotate the main
dial to select a different address for each IC-7700;
the range is 01h to DFh.
CI–V Transceive
ON
Transceive operation is possible with the IC-7700
connected to other Icom HF transceivers or receivers.
When ONis selected, changing the frequency,
operating mode, etc. on the IC-7700 automatically
changes those of connected transceivers (or receiv-
ers) and vice versa.
CI–V LANREMOTE Transceive Address
00h
Sets the CI-V address for sending the transceive
data from [LAN] to [REMOTE] or [RS-232C]. The
[REMOTE] or [RS-232C] connectors output the trans-
ceive data with this setting Address.
When your system are configured with any other
transceivers or receivers, and you do not want to
change their frequency or operating mode by operat-
ing the RS-BA1, sets this address different with 00h.
Only when you configure the remote control sys-
tem using an optional RS-BA1, you need this set-
ting.
The IC-PW1
can receive the transceive data from
other than 00h, so you can still operate the IC-PW1
by operating RS-BA1. In that case you must reset the
IC-PW1andsettheCI-Vsettingsagain.SeetheIC-
PW1’s instruction manual for details.
CI–V Output (for ANT)
OFF
Enables to output the antenna controller status (fre-
quency and so on) from [REMOTE].
•OFF :TurnsOFFthefunction.
•ON :Outputsthestatus.
RS–232C Function
CI–V
Select [RS-232C] connector output data format from
CI-VandDecode.
•CI-V :OutputsdatainCI-Vformat.(default)
•Decode :OutputsdecodedcontentsinASCIIcode
format.
Decode Baud Rate
9600
Selects data transmission speed (Baud rate) when
“Decode is selected in “RS-232C Function above;
settings are 300, 1200, 4800, 9600 and 19200 bps.
(default: 9600)
Keyboard Type
English
Selects the connected keyboard type from Japa-
nese, English, United Kingdom, French, French (Ca-
nadian), German, Portuguese, Portuguese (Brazil-
ian), Spanish, Spanish (Latin American) and Italian.
(default: English)
Other set mode (continued)