1. Introduction to the IDS X64
Thank you for purchasing an IDS Alarm Panel.
The IDS X64 is a versatile, Bylaw 25 compliant, expandable Alarm Panel. It has up to 8 partitions and can
be expanded from 8-64 zones. Most features are configurable and may be programmed directly through
a keypad or via serial PC connection or telephone system, using the IDS Download Software and
appropriate modem (P/N: 860-36-0001).
There are up to 64 programmable burglary zones, a dedicated panic zone, monitored siren output,
auxiliary power output, and 5 onboard programmable outputs expandable to 25, which may be
programmed to perform various trigger/switching functions.
For correct operation, the IDS X64 must be used in conjunction with the specified transformer / battery
combination (ask your sales representative for a copy of the IDS Power Budget spreadsheet to identify
your needs) and appropriate peripheral sensors and signalling devices.
NOTE:
X-SERIES products are not compatible with any previous IDS products, such as the IDS816 and
IDS1632.
1.1 Features of the IDS X64
Zones and Partitions:
8 onboard zones, expandable to 16 onboard zones with a X64 8-zone Plug-in Expander
(P/N: 860-06-X-08PI) A very cost-effective 16 zone solution
Further expandable to 64 zones with the use of up to 6 bus-wired X64 8-zone Unpowered
Expander modules (P/N: 860-06-X-08S) or 8 keypad zones - 1 per keypad
8 partitions
4 stay profiles per partition
Users:
128 users
Options to set user codes as Master, Duress, Maid, Arm only, Disarm only or Programmable
Output.
System Options:
Tamper reporting per zone using double end-of-line resistors (12K and 4K7)
5 programmable outputs on the Alarm Panel, expandable to 25 when using zone expanders (2
per expander), and keypads (1 per keypad)
Event log (1000 events) date and time relative
Auto arm/disarm capability per partition and by day of the week.
No movement auto arm and medical reporting
Panel firmware installer upgradable via serial data cable
Telephone communicator that supports Ademco, FBI, Silent Knight, Contact ID, and SIA
Fax defeat/answering machine override
Dual reporting provides for duplicated reporting to two independent central base stations
Split reporting to report to either 1 of 2 dual reporting number pairs
Comprehensive lightening protection
Dynamic battery self test
Low battery monitoring and cut-out circuit
Dual power supply, with an independent battery charging circuit, means more onboard power for
simplified alarm installation