Section: 9
IDS X64 Installer Manual 700-398-02D Issued August 2010
Table 23: Arm/ Disarm Days Data
Select the days to ARM (LEDs 1-7) and DISARM (LEDs 9-15) by toggling them on/off.
The valid data range is: 1 – 7, and 9 – 15. If no zone number LEDs are lit then it means it is disabled.
Auto Disarm Time (default = 2400)
This location sets the time at which a particular partition will auto disarm. To disable this location, enter
2400 as the time.
EXAMPLE:
To auto disarm at 06:00 am, enter 0600. All four digits must be entered, including any leading zeros
(0100 for 1 am).
Enter a 4-digit time for each of the 8 partitions and program as a 32-digit string, followed by
the [*] key.
[INSTALLER CODE] [*] [1] [8] [9] [*] [PARTITION NO.] [*] [HHMM] [*]
The valid data range is: 00h00m – 23h59m, with 24h00m to disable.
Partition no. is: 1-8.
Refer to section 8.3.2 Using Sub-locations to see how to scroll from one sub-location to another using the
[*] key.
NOTE:
For this auto disarm to be active; partition option 15 must be enabled in locations 221-228 and the
appropriate disarm days) selected in locations 181-188.
Auto Arm Delay (default = 0200 i.e. 2 minutes)
This location sets the delay period for the keypad buzzer warning, which is initiated before the panel auto
arms. At the completion of the Auto Arm Delay, the panel will arm. A valid user code entered during the
delay period will cancel the auto arming.
Enter a 4-digit time for each of the 8 partitions and program as a 32-digit string, followed by the
[*] key.
[INSTALLER CODE] [*] [1] [9] [0] [*] [PARTITION NO.] [*] [MMSS] [*]
The valid data range is: 00m01s – 59m59s.
Partition no. is: 1-8.