Section: 9
IDS X64 Installer Manual 700-398-02D Issued August 2010
Refer to section 8.3.2 Using Sub-locations to see how to scroll from one sub-location to another using the
[*] key.
9.10 Security Codes
Installer Code (default = 9999)
This location is used to change the installer code to a code that is more preferable.
[INSTALLER CODE] [*] [1] [9] [7] [*] [NEW INSTALLER CODE] [*]
Refer to section 8.2 Programming Standard Locations to see how to scroll through data in a location
using the [*] key.
NOTE:
Refer to location 23 to set the number of digits in the installer code.
Download Code (default = 9999)
This location is used to change the download code to a code that is more preferable.
The download code (in conjunction with the installer code) is required for download access to the Alarm
Panel.
A value of [10] programmed into location 34 will prevent the download code from being defaulted when
performing a hardware default.
[INSTALLER CODE] [*] [1] [9] [8] [*] [NEW DOWNLOAD CODE] [*]
NOTE:
If the panel is defaulted, the download code will revert to 9999. The download code is 4-digits in length.
Maintenance Code (default = 8888)
Users can be given limited access to installer mode by entering the maintenance code
programmed in this location.
Panel functions that can be edited in maintenance mode are:
Siren time
Siren delay
Keypad lockout count
Keypad sleep delay
All daylight savings settings
All partition auto arm settings
All no zone activity auto arm settings
All no zone activity alarm settings
[INSTALLER CODE] [*] [1] [9] [9] [*] [NEW MAINTENACE CODE] [*]
NOTE:
Refer to location 23 to set the number of digits in the maintenance code.