Section: 9
IDS X64 Installer Manual 700-398-02D Issued August 2010
52
Table 25: Partition Arm Options Data
LED
On / Off
Action
1
ON
Enable Instant Arm
OFF
Disable Instant Arm
2
ON
Enable Instant Key-switch Arm
OFF
Disable Instant Key-switch Arm
3
ON
Enable Quick Away Arm Key
OFF
Disable Quick Away Arm Key
4
ON
Enable Quick Stay Arm Key
OFF
Disable Quick Stay Arm Key
5
ON
Enable Auto Stay Arm if No Exit Zone is Triggered*
OFF
Disable Auto Stay Arm if No Exit Zone is Triggered*
6
ON
Enable Auto Stay Arm if No Exit Zone is Triggered When Arming with a Key-
switch*
OFF
Disable Auto Stay Arm if No Exit Zone is Triggered When Arming with a
Key-switch *
7
ON
Enable Forced Arm
OFF
Disable Forced Arm
8
ON
Enable Zone Bypassing
OFF
Disable Zone Bypassing
9
ON
Enable Arm with Zones in the Entry Route Violated
OFF
Disable Arm with Zones in the Entry Route Violated
10
ON
Enable Siren Toot on Arm
OFF
Disable Siren Toot on Arm
11
ON
Enable Siren Toot on Disarm
OFF
Disable Siren Toot on Disarm
12
ON
Enable the Entry Beep
OFF
Disable the Entry Beep
13
ON
Enable the Exit Beep
OFF
Disable the Exit Beep
14
ON
Enable Engineer's Reset
OFF
Disable Engineer's Reset
15
ON
Enable Auto Disarm
OFF
Disable Auto Disarm
Default values are shaded
* For option 5 or 6 to work, option 2 needs to be disabled.