Section: 9
IDS X64 Installer Manual 700-398-02D Issued August 2010
60
Enter a 2-digit reporting code for each of the 16 zones and program as a 32-digit string,
followed by the [*] key.
[INSTALLER CODE] [*] [LOCATION] [*] [ZONE NO.] [*] [REPORTING CODE] [*]
The valid data range is: 01-FF, with 00 to disable.
If any of the sub-locations are disabled here, then the reporting codes will not report even if they are
enabled at 9.16 Event Reporting Options - Advanced.
Refer to section 8.3.2 Using Sub-locations to see how to scroll from one sub-location to another using the
[*] key.
NOTE:
The values are hexadecimal. Refer to Table 3 on how to program hexadecimal values.
LOCATIONS 308 - 311
Zone Alarm Restoral Reporting Code
The 2-digit zone restoral code is reported when the zone has returned to the “unviolated” condition after
triggering an alarm. Option 2 in Table 40 needs to be enabled.
Each location represents a set of 16 zones:
Location 308 is zones 1-16
Location 309 is zones 17-32
Location 310 is zones 33-48
Location 311 is zones 39-64
Enter a 2-digit reporting code for each of the 16 zones and program as a 32-digit string,
followed by the [*] key.
[INSTALLER CODE] [*] [LOCATION] [*] [ZONE NO.] [*] [REPORTING CODE] [*]
The valid data range is: 01-FF, with 00 to disable.
If any of the sub-locations are disabled here, then the reporting codes will not report even if they are
enabled at 9.16 Event Reporting Options - Advanced.
Refer to section 8.3.2 Using Sub-locations to see how to scroll from one sub-location to another using the
[*] key.
NOTE:
The values are hexadecimal. Refer to Table 3 on how to program hexadecimal values.
LOCATIONS 312 - 315
Zone Tamper Reporting Code
The 2-digit tamper code is reported if tamper by zone has been enabled and a zone tamper occurs.
Option 5 in Table 40 needs to be enabled.
Each location represents a set of 16 zones:
Location 312 is zones 1-16
Location 313 is zones 17-32
Location 314 is zones 33-48
Location 315 is zones 39-64
Enter a 2-digit reporting code for each of the 16 zones and program as a 32-digit string,
followed by the [*] key.

Table of Contents