IDS X64 Installer Manual 700-398-02D Issued August 2010
45
9.8 No Movement - Advanced
LOCATION 171
No Movement Auto Arm Time Out (default =00)
If no violations are registered for the period of time specified in this location then the alarm will auto arm.
This may be used if you forget to arm when leaving for work; the alarm will then automatically away arm
itself if no violations were registered.
This function is only available if values have been programmed into locations 172 and 173.
This No Movement Auto Arm event reports a close event, using user number 133, but only if CID or SIA
reporting has been selected.
Enter a 2-digit duration in hours for each of the 8 partitions and program as a 16-digit string,
followed by the [*] key.
[INSTALLER CODE] [*] [1] [7] [1] [*] [PARTITION NO.] [*] [AUTO ARM TIME OUT] [*]
The valid data range is: 01 23, with 00 to disable.
Partition no. is: 1-8.
Refer to section 8.3.2 Using Sub-locations to see how to scroll from one sub-location to another using the
[*] key.
NOTE:
If this location is disabled, then by default, locations 172 and 173 will also be disabled. This means that
even if you put values into locations 172 and 173, no movement auto arm will not commence.
LOCATION 172
No Movement Auto Arm Start (default = 0000)
Program the start time to start checking for no movement. For example, if you leave your premises at
06:50 am, program the start time to be 07:00.
Enter a 4-digit time [HHMM] for each of the 8 partitions and program as a 32-digit string,
followed by the [*] key.
[INSTALLER CODE] [*] [1] [7] [2] [*] [PARTITION NO.] [*] [HHMM] [*]
The valid data range: 00h00m 23h59m.
Partition no. is: 1-8.
Refer to section 8.3.2 Using Sub-locations to see how to scroll from one sub-location to another using the
[*] key.
LOCATION 173
No Movement Auto Arm End (default = 2400)
Program the end time to stop checking for no movement. For example, using 07:00 programmed into
location 172 and if 2 hours is needed, then program 09:00.
Enter a 4-digit time [HHMM] for each of the 8 partitions and program as a 32-digit string,
followed by the [*] key.
[INSTALLER CODE] [*] [1] [7] [3] [*] [PARTITION NO.] [*] [HHMM] [*]