IDS X64 Installer Manual 700-398-02D Issued August 2010
53
LOCATIONS 221 - 228
Extra Partition Options (Partitions 1 - 8)
These locations are used to configure extended options for each partition. Refer to Table 26 for
the values that can be selected.
Each location represents a partition:
Location 221 is partition 1
Location 222 is partition 2
Location 223 is partition 3
Location 224 is partition 4
Location 225 is partition 5
Location 226 is partition 6
Location 227 is partition 7
Location 228 is partition 8
(This is an advanced location).
Table 26: Extended Partition Options Data
LED
On/ Off
Action
1
ON
Enable Automatic Re-enabling of Shutdown Zones at the Time of the Dialler test
OFF
Disable Automatic Re-enabling of Shutdown Zones at the Time of the Dialler test
2
ON
Enable Bypassing of Common Zones
OFF
Disable Bypassing of Common Zones
3
ON
Enable Delay Before Communications
OFF
Disable Delay Before Communications
4
ON
Enable Keypad Lockout
OFF
Disable Keypad Lockout
5
ON
Enable Silent Keypad Panic
OFF
Disable Silent Keypad Panic
Default values are shaded
9.12 Delays
LOCATION 230
Exit Delay Period (default = 0030)
The exit delay period is the amount of time between arming the panel and successfully exiting the
premises without violating Entry/Exit and Follower zones.
The exit delay will begin after the system is armed by either:
Entering a valid user code
Pressing the [1] key and holding it down until the system is armed
Pressing the [6] key and holding it down until the system is armed
Enter a 4-digit exit delay period for each of the 8 partitions and program as a 32-digit string,
followed by the [*] key.
[INSTALLER CODE] [*] [2] [3] [0] [*] [PARTITION NO.] [*] [MMSS] [*]