Section: 9
IDS X64 Installer Manual 700-398-02D Issued August 2010
Extra Partition Options (Partitions 1 - 8)
These locations are used to configure extended options for each partition. Refer to Table 26 for
the values that can be selected.
Each location represents a partition:
Location 221 is partition 1
Location 222 is partition 2
Location 223 is partition 3
Location 224 is partition 4
Location 225 is partition 5
Location 226 is partition 6
Location 227 is partition 7
Location 228 is partition 8
(This is an advanced location).
Table 26: Extended Partition Options Data
Enable Automatic Re-enabling of Shutdown Zones at the Time of the Dialler test
Disable Automatic Re-enabling of Shutdown Zones at the Time of the Dialler test
Enable Bypassing of Common Zones
Disable Bypassing of Common Zones
Enable Delay Before Communications
Disable Delay Before Communications
Enable Silent Keypad Panic
Disable Silent Keypad Panic
Default values are shaded
Exit Delay Period (default = 0030)
The exit delay period is the amount of time between arming the panel and successfully exiting the
premises without violating Entry/Exit and Follower zones.
The exit delay will begin after the system is armed by either:
Entering a valid user code
Pressing the [1] key and holding it down until the system is armed
Pressing the [6] key and holding it down until the system is armed
Enter a 4-digit exit delay period for each of the 8 partitions and program as a 32-digit string,
followed by the [*] key.
[INSTALLER CODE] [*] [2] [3] [0] [*] [PARTITION NO.] [*] [MMSS] [*]