Low Battery Monitoring
This trouble condition can be caused by a low battery voltage, a dead battery, or no
battery. If the battery is there, try charging it. If this not does work, then the battery needs
to be replaced.
This trouble condition will only clear once the battery voltage has been restored.
Aux 12V Monitoring
This trouble condition indicates that the fuse has blown, or that there is a fault
This trouble condition will only clear once the fault has been restored.
Engineer’s Reset
An alarm condition has occurred, the Installer needs to come and clear the condition by
entering an installer code. The panel cannot be armed until this has occurred, nor will the
trouble condition clear.
Box Tamper
The metal housing where the panel is stored has been opened.
To clear trouble condition, make sure the door to the housing is closed and then view the
trouble condition.
Bus-wired Peripheral Tamper
A peripheral device could be a keypad, remote receiver or bus-wired zone expander.
This trouble condition indicates that one of these devices has been tampered with.
To clear this trouble condition, restore the tampered device and then view the tamper.
Bus-wired Peripheral Fail
The panel has lost communication to one of the peripherals attached to it.
Bus-wired Peripheral Low Power / Battery
Supply voltage to a peripheral has dropped below the recommended limit.
EEPROM
The panel is not communicating correctly due to a serious error.
The siren time out period is the period of time for which the siren will sound after it has been
activated.
To program the time into this location, the format is [MMSS].
[INSTALLER CODE] [*] [1] [7] [*] [MMSS] [*]
The valid data range is: 00m01s – 59m59s.
This location sets the siren delay period between when an audible alarm condition is registered
and the siren is activated. The alarm condition will however be reported to the base station as soon as it
occurs. Panic zones and Fire zones will cause an immediate siren even if siren delay is programmed.
Option 7 in location 14 (Global Options) must be enabled for the siren delay to have an effect.
To program the time into this location, the format is [MMSS].
[INSTALLER CODE] [*] [1] [8] [*] [MMSS] [*]
The valid data range is: 00m01s – 59m59s.