EasyManua.ls Logo

IDS X64

IDS X64
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section: 9
IDS X64 Installer Manual 700-398-02D Issued August 2010
27
The valid data range is: 1 255.
Table 8: Loop Response Time Data
Value
Response Time
Value
Response Time
1
12 ms
30
360 ms
2
24 ms
45
540 ms
3
36 ms
60
720 ms
4
48 ms
75
900 ms
5
60 ms
90
1.08 seconds
6
72 ms
105
1.26 seconds
7
84 ms
120
1.44 seconds
8
96 ms
135
1.62 seconds
9
108 ms
150
1.80 seconds
10
120 ms
165
1.98 seconds
11
132 ms
180
2.16 seconds
12
144 ms
195
2.34 seconds
13
156 ms
210
2.52 seconds
14
168 ms
225
2.70 seconds
15
180 ms
240
2.88 seconds
16
192 ms
255
3.06 seconds
LOCATION 12
Cross-zone Delay Time (default = 0030)
This location defines the cross-zone delay timer period in minutes and seconds, and it is used
in conjunction with location 13. (This is an advanced location).
To program the time into this location, the format is [MMSS].
[INSTALLER CODE] [*] [1] [2] [*] [MMSS] [*]
The valid data range is: 00m00s 59m59s.
LOCATION 13
Cross-zone Count (default = 3)
If the panel is armed and the total number of violations of zones programmed as cross-zones
(locations 101-164) reaches this count within the time period programmed into location 12, an alarm
condition will be registered. Any single zone enabled as a cross-zone, which is violated continuously for
the time specified in location 12 will also register an alarm condition.
[INSTALLER CODE] [*] [1] [3] [*] [CROSS-ZONE COUNT] [*]
The valid data range is: 1 - 15, with 0 to disable.